Environmental and Battery Test Systems Engineered for Global Qualification Programs
[email protected] Global Engineering Support
Get Quote

Temperature Humidity Test Chamber

Bellue’s temperature and humidity chamber supports controlled environmental exposure and thermal cycling tests for products and components. The listed BTH models cover 80 L to 1000 L workspaces; confirm the required temperature-humidity profile, specimen load, and configuration when requesting a quotation.

Temperature Humidity Test Chamber Parameters

Model BTH-80 BTH-150 BTH-408 BTH-800 BTH-1000
Test Space W x H x D (mm) 400x500x400 500x600x500 600x850x800 1000x1000x800 1000x1000x1000
External Dimension W x H x D (mm) 650x1650x1270 700x1700x1370 800x1800x1620 1200x1900x1620 1200x1900x1820
Cooling Method Air-cooling Air-cooling Air-cooling Air-cooling Air-cooling
Temperature Range A:-0~150℃   B:-20~150℃   C:-40~150℃   D:-70~150℃
Humidity Range 20%RH-98%RH (confirm the temperature-humidity operating envelope for the quoted configuration).
Temperature Fluctuation ±0.5℃
Humidity Fluctuation ±2%RH
Temperature Deviation ≤2.0℃
Humidity Deviation A)>75%RH:≤+2,-3%RH,B)<75%RH:≤±5%RH。
Temperature Uniformity ≤±2.0℃
Humidity Uniformity +2,-3%RH
Heating Rate Approx 3℃/mins,average non-linear ,no load
Cooling Rate Approx 1℃/ mins,average non-linear ,no load
Temperature Overshoot ≤±2℃
Internal Material 1.2mm thick SUS#304 high &low temperature resistance stainless steel.
External Material Adopt flame retardant high strength PU Polyurethane foam insulation material.
Control Method Touch screen programmable PLC, with USB interface, with RS-485 interface can be connected to computer controlling, special network control software, convenient remote monitoring, data acquisition.
Compressor Tecumseh (France)-fully air-cooled double-fall cooling compressor. Or Bock (Germany) semi-enclosed air-cooled refrigeration.
Safety Protection Explosion-proof pressure relief device, explosion-proof chain, mobile phone alarm device, networking, smoke exhaust device, fire extinguishing device, etc.

 

Temperature Humidity Test Chamber Application

Bellue’s temperature and humidity chamber supports controlled environmental exposure and thermal cycling tests for products and components. The listed BTH models cover 80 L to 1000 L workspaces; confirm the required temperature-humidity profile, specimen load, and configuration when requesting a quotation.

The listed configuration uses a programmable touch-screen controller for temperature and humidity settings. Confirm the operating envelope, measurement requirements, communication interfaces, and data export options for the selected model.

Share specimen dimensions, quantity, heat dissipation, exposure duration, utilities, and acceptance requirements so the quotation can define the equipment and installation scope.

Features of Temperature Humidity Test Chamber

  1. Confirm the refrigeration configuration and energy consumption against the required temperature profile and site conditions.
  2. Easy operation, available for both fixed value test and programmable test.
  3. Available for the customized design and provide various options to meet different test requirements.
  4. RS485 and RJ45 communications, available to computer remote control.
  5. Fog-free observation window and interior light to view product under test.

 

Temperature Humidity Testing Standard

  • IEC 68-2-1  Environmental testing – Part 2: Test methods – Tests A: Cold
  • IEC 68-2-2  Environmental testing for electrical and electronic products Test methods – Tests B: Dry Heat
  • IEC68-2-3  Environmental testing for electrical and electronic products – Part 2: Testing method test Cab: Damp heat Steady state
  • IEC 68-2-30  Environmental testing for electrical and electronic products – Part 2: Test method – Test Db: Damp heat, cyclic (12h+12h cycle)
  • IEC 68-2-14  Environmental testing for electrical and electronic products-Part 2:Test methods-Test N: Change of temperature
  • MIL-STD-810D  High temperature test
  • MIL-STD-810D  Low temperature test
  • MIL-STD-810D  Damp heat test

 

Temperature Humidity Test Chamber Common Faults and Troubleshooting

Use the operating manual for your chamber model when reviewing alarms, operator checks, and maintenance requirements. Share the observations below with Bellue so the service team can review the symptoms and define the next support step.

  1. Temperature does not reach the setpoint or becomes unstable. Record the programmed temperature, actual temperature trend, elapsed time, specimen load, and any alarm messages. Include whether the issue occurs during heating, cooling, or a hold period.
  2. Cooling performance changes. Share the starting and target temperatures, the time-temperature record, room conditions, sample arrangement, and any recent changes to the test or installation. Use the model manual to identify the operator checks relevant to your equipment.
  3. Humidity differs from the target. Record the temperature and humidity setpoints, measured values, duration, water-supply observations, and controller messages. Confirm the installed humidity-sensing and water-system configuration before planning maintenance.
  4. An alarm interrupts the test. Save the alarm code, time, test stage, and controller record. Follow the model manual for the alarm response and send the records to Bellue for troubleshooting or repair coordination.

For support, include the model, serial number if available, installation location, maintenance history, and relevant photos or controller records. Review parts and repair support or schedule service.

Scroll to Top