Temperature Cycling Test Chamber
Bellue’s temperature cycling chamber exposes specimens to alternating high and low temperatures for controlled thermal cycling tests. Confirm the temperature profile, specimen load, dwell time, humidity requirements, and acceptance criteria when selecting a configuration.
Performance parameters
| Model | BTKS5-150C | BTKS5-225C | BTKS5-408C | BTKS5-800C | BTKS5-1000C |
|---|---|---|---|---|---|
| Testing Space | 500x600x500 | 500x750x600 | 600x850x800 | 1000x1000x800 | 1000x1000x1000 |
| W x H x D (mm) | |||||
| External Dimension | W750xH1780xD1500mm | ||||
| Cooling Mode | Air-cooled | Air-cooled | Air-cooled | Water-cooled | Water-cooled |
| Power Source | 8KW | 10KW | 13KW | 30KW | 32KW |
| Temperature Range | -70℃~+150℃(Adjustable) | ||||
| Humidity Range | 20%RH-98%RH (confirm the temperature-humidity operating envelope for the quoted configuration). | ||||
| Temperature Fluctuation | ±0.5℃ | ||||
| Humidity Fluctuation | ±2%RH | ||||
| Temperature Deviation | ≤2.0℃ | ||||
| Humidity Deviation | A)>75%RH:≤+2,-3%RH,B)<75%RH:≤±5%RH。 | ||||
| Temperature Uniformity | ≤±2.0℃ | ||||
| Humidity Uniformity | +2,-3%RH | ||||
| Heating Rate | From -40℃ to 85℃,full range non-linear average about 5℃/mins,no load | ||||
| Cooling rate | From 80℃to -40℃ ,full range non-linear average about 5℃/mins,no load | ||||
| Temperature Overshoot | ≤±2℃ | ||||
| Internal Material | 1.2mm thick SUS#304 temperature resistance stainless steel. | ||||
| External Material | Galvanized plate with Double-sided electrostatic powder coating. | ||||
| Control Mode | Touch screen programmable PLC, with USB interface, with RJ485 interface can be connected to computer controlling, special network control software, convenient remote monitoring, data acquisition. | ||||
| Compressor | Tecumseh (France)-fully air-cooled double-fall cooling compressor. Or Bock (Germany) semi-enclosed air-cooled refrigeration. | ||||
| Safety Protection | Explosion-proof pressure relief device, explosion-proof chain, mobile phone alarm device, networking, smoke exhaust device, fire extinguishing device, etc. | ||||
Standards
- IEC 62133-2017
- UL 1642
- UN 38.3