Main technical parameters
| Model | BE-8103 |
|---|---|
| Structure | All-in-one structure, the door uses explosion-proof lock + explosion-proof chain |
| Temperature Range | Normal temperature to 150°C (Adjustable) |
| Controlling Accuracy | ±0.5℃ |
| Temperature Deviation | ±2.0℃, No load |
| Heating Rate | RT~150°C (Linear 5°C/min) |
| Control Display | PLC touch type (7 inch) + remote control |
| Working Cabinet Dimension | W600XD500XH600 mm |
| External Dimension | W940XD780XH1620 mm |
| Inner Chamber Material | SUS304 Stainless steel with mirror-finish |
| External Chamber Material | SECC steel plate, fine powder paint coating (thickness 1.5mm) |
| Bottom | With universal wheel |
| Observation Window | 390 X 360mm (20mm thick explosion-proof glass, explosion-proof mesh) |
| Insulation Material | Imported high-density glass wool, good heat insulation, to ensure maximum temperature insulation, tight sealing materials for high temperature resistant silicone, withstanding high temperatures over 300 degrees for a long time |
| Terminal Hole | Diameter 50mm Terminal hole on the left and right sides |
| Power Supply | 220V / 50HZ / 4.0KW |
| USB Interface | With USB interface, the test data can be exported |
| Auxiliary Function | Explosion-proof pressure relief device, smoke exhaust device, explosion-proof lighting device, electronic door lock system, safety stop switch |
Standards
- IEC 62133-2017
- UL 1642
- GB 31241-2014
Define the Thermal Abuse Test Program
Use the applicable standard edition and laboratory-approved procedure to define specimen preparation, temperature exposure, monitoring, and evaluation. Confirm whether the project concerns individual cells, batteries, or modules, and whether the selected chamber and protective configuration fit that scope.
- Battery chemistry, application, specimen dimensions, mass, quantity, and state of charge.
- Required temperature profile, loaded heating rate, dwell time, and sensor locations.
- Observation, data recording, stopping criteria, and post-exposure evaluation.
- Fixtures, feedthroughs, exhaust interfaces, utilities, and installation conditions.
Send the approved test method and specimen details with the RFQ so the equipment and acceptance scope can be reviewed for the project.