Performance Parameters
The figures below are from the original product listing. Confirm the selected model, per-cabinet usable space, loaded performance, supplied hardware and acceptance criteria in the quotation.
Model Comparison
| Model | BTL-D2-252C | BTL-D2-288C |
|---|---|---|
| Single Cabinet Inner Dimension | W600 × D700 × H600 mm | W800 × D600 × H600 mm |
| External Dimension | W1300 × D1800 × H1950 mm | W1500 × D1700 × H1950 mm |
| External Chamber Material | Listed: 1.2 mm galvanized sheet with a high-temperature plasticized coating. | Not separately stated in the original listing; confirm for the quoted model. |
| Power Supply | Listed: AC 380 V, 50 Hz, 12 kW. Confirm phase and rating basis. | Listed: AC 380 V, 50 Hz, 14 kW. Confirm phase and rating basis. |
Common Listed Specifications
| Specification | Listed Details and Confirmation Scope |
|---|---|
| Structure Mode | Listed: integral structure with upper and lower cabinets. Confirm usable space, control arrangement and simultaneous operation. |
| Temperature Range | Listed: −40°C to +150°C. Confirm the operating envelope for each cabinet and the required load. |
| Temperature Fluctuation | Listed: ±0.3°C. Confirm measurement location, operating setpoint, load and assessment period. |
| Heating Rate | Listed: average 1–3°C/min; nonlinear and no load. Confirm the temperature interval and measurement method. |
| Cooling Rate | Listed: average 1.0°C/min over the full range; nonlinear and no load. Confirm the measurement method and required loaded profile. |
| Temperature Uniformity | Listed: ≤±2°C at no-load, steady conditions. Confirm sensor positions, usable volume and assessment method. |
| Observation Window | Listed: three-layer vacuum tempered glass. Confirm the supplied construction and observation requirements. |
| Test Terminal | Listed: 12 sets of terminals. Confirm quantity per cabinet or total, electrical ratings and included wiring. |
| Cooling Mode | Listed: air cooling; water cooling optional. Confirm the supplied cooling configuration and site connections. |
| Compressor | Original listing: Tecumseh (France). Confirm supplied compressor manufacturer, model and configuration. |
| Controlling Mode | Programmable touchscreen PLC control with listed USB and RS485 interfaces. Confirm protocol, software scope, logging channels and remote-control functions. |
| Internal Chamber Material | Listed: 1.0 mm SUS304 stainless steel with a mirror finish and a Teflon insulation coating. Confirm coating identity, coverage, electrical limits and temperature limits. |
| Safety Protection | Pressure relief, door restraint, alarm, remote operation, exhaust and fire-response provisions are listed. Confirm supplied hardware, ratings and limits for the specified specimens and battery energy. |
| Extension Function | Communication interface for integration with a separately specified charge-discharge system. Confirm protocol, interlocks and included equipment in the quotation. |
Loaded Performance and Acceptance
The listed heating and cooling rates are nonlinear, no-load averages. Specify specimen and fixture mass, powered heat dissipation, sensor locations and the required profile for each cabinet. Agree loaded acceptance criteria for one-cabinet operation and simultaneous operation, including the required setpoints, dwell times, logging and recovery conditions.
Application
A double-deck format provides upper and lower test cabinets for temperature testing of products and components. The original listing gives a −40°C to +150°C range. Confirm whether the quoted configuration supports independent controls, separate profiles and simultaneous operation with the specified loads.
For battery charge-discharge testing, confirm the cycler interface, battery type and energy, enclosure protection, exhaust, and emergency response configuration in the project specification.
Features and Configuration
- Programmable temperature control, heating, refrigeration and forced circulation as specified for the ordered configuration.
- Confirm separate setpoints, logging and the simultaneous operating envelope for the two cabinets, including powered specimen heat loads.
- Request documented specimen protection, exhaust and fault-response provisions for the project. Confirm any required explosion-protection rating for the supplied configuration.
Test Method Selection
Define the governing standard edition, procedure, specimen operating state, temperature, dwell time and measurement locations in the RFQ and acceptance plan.
- IEC 60068-2-1:2025 covers cold testing.
- IEC 60068-2-2:2025 covers dry-heat testing.
The IEC 2025 editions replace the corresponding 2007 editions. Identify an older edition explicitly when it is required by the contract. Specify temperature-change procedures separately. For GB, GJB or battery qualification projects, provide the exact edition and procedure so the quoted chamber capability and specimen protection can be reviewed.
Installation and Operating Scope
Use the supplied equipment manual and approved site procedures for installation, operation and maintenance. Have qualified personnel confirm protective earthing, electrical connections, specimen power interfaces, cabinet positioning, access and maintenance responsibilities. Agree guarding, protection, fault response and energy-isolation procedures for the supplied configuration before commissioning.
Confirm the approved specimen types, loading arrangement, powered heat input and operating limits. Discuss humidity requirements separately when the project needs temperature and humidity testing.
Video Reference
Use the video as a general equipment reference. Confirm the model and supplied configuration with Bellue for the quoted system.