Performance parameters
| Model | BE-8106 |
|---|---|
| Structure | All-in-one structure, the door uses explosion-proof lock and explosion-proof chain |
| Drop Ball Weight | 9.1kg±0.1kg |
| Dropping Height | 0~770mm(Adjustable) |
| Control Mode | PLC Touch Screen Control+ Remote Control |
| Crossing Bar Diameter | 15.8 mm |
| Inner Cabinet Dimension | W500 X D300 X H800mm |
| Effective Test Space | W300XD300XH300mm |
| Internal Material | 1.0mm thickness SUS 304# Stainless steel (reinforced). Total 80mm thickness together with external chamber. |
| External Material | 1.5mm thickness Cold-rolled plate |
| Air Vent | Diameter: 150mm, at the top of chamber back |
| Observation Window | 390 X 360mm (20mm thick explosion-proof glass, install explosion-proof stainless steel mesh) |
| Lifting Mode | Electric |
| Top / Bottom Impact Surface | Steel Plate |
| Test Space | W300XD400XH200 mm |
| Overall Dimensions | W940XD780XH1620 mm |
| Power Supply | AC 220V / 2.0KW |
| Data Output | Test data can be output by USB flash disk directly . |
| Safety Protection | Explosion-proof pressure relief device, smoke exhaust device, fire extinguishing system, electronic door lock system, safety stop switch |
| Options | Temperature acquisition system, voltage acquisition system, video monitoring system |
Application
The battery impact test chamber applies a controlled impact using the specified drop mass, drop height, and crossing bar to assess the battery’s response.
Confirm the sample type, fixture, test conditions, and applicable standard edition for the project. Pass/fail criteria must be taken from the approved test method.
Test requirements
- UL 1642
- UN 38.3