Thermal Shock Test Chamber (Three Zone)
Bellue’s three-zone thermal shock chamber keeps the specimen in a stationary test zone and switches hot and cold air from separate storage zones. Confirm the temperature profile, specimen load, exposure time, and recovery criteria for the selected configuration.
Performance parameters
| Model | BTS-50 | BTS-80 | BTS-150 | BTS-250 | BTS-512 | BTS-1000 |
|---|---|---|---|---|---|---|
| Test Space | 350x400x360 | 400x500x400 | 500x600x500 | 600x700x600 | 800x800x800 | 1000x1000x1000 |
| W x H x D (mm) | ||||||
| External Dimension | 1320x1860x1420 | 1320x2180x1520 | 1450x2200x1700 | 1550x2280x1800 | 1800x2300x2000 | 2000x2350x2300 |
| W x H x D (mm) | ||||||
| Pre-cooling Zone Temp. | -10~-80℃ | |||||
| Pre-heating Zone Temp. | +50~+220℃ | |||||
| Pre-cooling Zone Cooling Rate | -10~-40℃<30 mins -10~-60℃<50 mins -10~-80℃<65 mins | |||||
| Pre-heating Zone Heating Rate | +50~150℃<30 mins +50~180℃<50 mins +50~220℃<60 mins | |||||
| Temp. Shock Range | B type :-40~150℃ C Type :-55~150℃ D Type :-65~150℃ | |||||
| Temp. Recovery Time | ≤5mins | |||||
| High low Temp. Exposure Time | <30 mins | |||||
| Temp. Fluctuation | ≤±0.5℃ | |||||
| Internal Material | 1.2mm thick SUS#304 high &low temperature resistance stainless steel. | |||||
| External Material | Adopt flame retardant high strength PU Polyurethane foam insulation material. | |||||
| Control Method | Touch screen programmable PLC, with USB interface, with RS485 interface can be connected to computer controlling, special network control software, convenient remote monitoring, data acquisition. | |||||
| Compressor | Tecumseh (France)-fully air-cooled double-fall cooling compressor. Or Bock (Germany) semi-enclosed air-cooled refrigeration. | |||||
Application of Thermal Shock Chamber
Bellue’s three-zone thermal shock chamber keeps the specimen in a stationary test zone and switches hot and cold air from separate storage zones. Confirm the temperature profile, specimen load, exposure time, and recovery criteria for the selected configuration.
Features
- Stationary specimen arrangement with switched hot and cold air exposure.
- Confirm temperature recovery under the specified specimen load and exposure conditions.
- Cable port available for data acquisition.
- RS485 communication, Ethernet, available for computer remote control
- Programmable temperature exposure cycles.
Standards for Project Review
Confirm the applicable standard edition, procedure, and acceptance criteria against the selected chamber configuration.
- IEC68-2-1 Environmental testing – Part 2: Test methods – Tests A: Cold
- IEC68-2-2 Environmental testing for electrical and electronic products Test methods – Tests B: Dry Heat
- MIL-STD-810D Environmental test methods and engineering guidelines
Operation precautions
Review the operating manual and installation requirements for the delivered configuration before use. Confirm specimen suitability, cable routing, utilities, and authorized operating conditions for the approved test program.
- The thermal shock test machine body cannot press the power line, nor can it be stepped on the power line;
- Do not spray or rinse the equipment directly with water, and do not place the equipment in a damp, easily splashed place, so as not to affect the electrical insulation performance of the equipment;
- It is strictly forbidden to use it when the power line is damaged or the plug is worn out, because the wear or damage of the power line may cause an electric shock to the operator, and must be replaced by a professional electrician according to the provisions of the thermal shock test chamber;
- In order to ensure the safety of operators, do not place electrical sockets, stabilized power supplies and other electrical appliances on the table of the equipment, and it is also prohibited to use electrical appliances inside the equipment to avoid electromagnetic interference and malfunction;
- It is strictly forbidden to put inflammable and explosive dangerous goods, as well as strong corrosive acids and alkalis;
- It is strictly forbidden to place or use gasoline and other flammable materials near the thermal shock test equipment to avoid fire.