Temperature Control Battery Short Circuit Test Chamber
Bellue’s BE-8102 chamber supports controlled external short-circuit testing of batteries under selected temperature conditions. Confirm the complete circuit resistance, current, temperature, duration, and monitoring requirements against the applicable test procedure and battery under test.
Performance parameters
| Model | BE-8102 |
|---|---|
| Structure | All-in-one structure, the door uses explosion-proof lock and explosion-proof chain |
| Max. short-circuit current | 1000A |
| Internal Resistance | 80±20 mΩ (Load-current 400A) |
| Remote Control Available Distance | 7 meters without solid barrier |
| Controlling Mode | PLC touch type (7 inch) + remote control |
| Mechanical Life | 300 thousand times |
| Electric Life | Resistive load 50,000 times |
| Temperature Range | Normal temperature to 80°C or 0-80°C (Optional) |
| Temperature Fluctuation | ±1℃ |
| Temperature Deviation | ±2℃ |
| Inner Chamber Dimension | W600 X D500 X H600mm |
| Inner Chamber Material | 1.0mm thickness 304# stainless steel |
| External Chamber Dimension | W940XD780XH1620 mm |
| External Chamber Material | Cold-rolled sheet paint with1.5mm thickness, total thickness together with inner chamber is 100mm) |
| Observation Window | 390 X 360mm (20mm thick explosion-proof tempered glass) and protective steel mesh |
| Power Supply | AC220V / 3.0KW |
| Data Output | Current and voltage temperature can be recorded with the interface display. The test data can be directly output by USB flash disk |
| Security System | Explosion-proof pressure relief device, smoke exhaust device, fire extinguishing system, electronic door lock system, safety stop switch |
| Options | Temperature acquisition, voltage acquisition system, video monitoring system |
Application
- Designed for controlled external short-circuit testing of batteries under the selected temperature conditions.
- Confirm the required circuit resistance, current, temperature, duration, and acceptance criteria against the applicable standard revision and the battery under test. The listed BE-8102 configuration specifies an internal resistance of 80 ± 20 mΩ at a load current of 400 A; requirements for the complete test circuit must be confirmed for the project.
- Current, voltage, and temperature can be recorded, and test data can be exported via USB. Refer to the parameter table for the listed safety features and optional measurement systems.
Test requirements
- IEC 62133-2017
- UL 1642
- UN 38.3