Phone:+86 180 0288 0096            E-mail:sales@belltestchamber.com

Traction Battery Short Circuit Test Machine

The Traction Battery Short Circuit Test Machine is applicable to the standard UL 2580.

Technical Parameters

Model BE-XL-2000A BE-XL-3000A BE-XL-5000A
Max. Operating Current(A) 2000A 3000A 5000A
Max. Instantaneous Current(A) 3000A 4000A 6000A
Temp. Range Ambient Temperature
Inner Resistance <1mΩ,<5mΩ,<10mΩ,<20mΩ,<50mΩ,<100mΩ(Optional)
Control Mode PLC Touch Screen + Computer remote control + Remote controller
Overall Dimension W700xD1050xH1830mm
Explosion proof Chamber Dimension 800 X 800 X 800mm,1000 X 1000 X 1000mm (Optional)
Voltage Measurement Range 0~500V
Short Circuit Response Time ≦20ms
Data Interface USB, Data card, etc.
Data Acquisition Module Independent remote acquisition, multi-voltage/temperature/current acquisition channels ensure data accuracy. Acquisition frequency 100HZ
Short Circuit Mode Pneumatic + vacuum arc extinguishing
Safety Device Electric leakage, over current protection ,smoke alarm device, abnormal sound light alarm.
Testing Fixture Customize according to actual testing condition
Power Supply 220V 50HZ

 

Standard

  • UL 2580

 

Battery Short Circuit Test Machine Relevant standard requirement

Single Storage Cell Safety Test

6.2.4 Short circuit

  1. Charge the single storage cell according to 6.1.3 standard
  2. The cell is to be short-circuited by connecting the positive and negative terminal with an external resistance of less than 5mΩ for 10 min
  3. Observe for 1H

 

Battery module safety test

6.3.4 Short circuit

  1. Charge the battery module according to standard 6.1.4
  2. The battery module is to be short-circuited by connecting the positive and negative terminal with an external resistance of less than 5mΩfor 10 min
  3. Observe for 1H

Request Quote

Thank you for your interest in  our test chambers. Please complete the form, we can provide quick and effective service within 12 hours. If this is an urgent matter, please contact us via phone, thanks.